1.
Braz. j. med. biol. res ; 48(7): 644-649, 07/2015. tab, graf
Article in English | LILACS | ID: lil-751345

ABSTRACT

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.


Subject(s)
Adult , Humans , Male , Cytokines/blood , HIV Infections/blood , Lymphoma, AIDS-Related/blood , Lymphoma, B-Cell/blood , Lymphoma, B-Cell/virology , Biomarkers, Tumor/blood , Bisexuality , Case-Control Studies , HIV Infections/immunology , Homosexuality , Inflammation/blood , Inflammation/immunology , Inflammation/virology , Lymphocyte Activation , Lymphoma, AIDS-Related/immunology , Lymphoma, B-Cell/immunology , Multivariate Analysis
2.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.91-92, ilus, graf.
Monography in Portuguese | LILACS | ID: lil-236261

ABSTRACT

Apresentamos neste trabalho os resultados iniciais de uma nova proposta de aparato para o estudo do tempo de trânsito esofagiano em voluntários assintomáticos de um bolus de alimento-teste AT (10 ml de iogurte) marcado com 5g de pó de ferrita (estudo biomagnético, B) e com 350 MBq de (99m)Tc (estudo cintilográfico, C). Para B este novo aparato consiste de uma configuração de espiras em oposição de fase excitada por um sinal senoidal de 10 kHz. O sinal de resposta é obtido quando o AT passa entre os arranjos de bobinas posicionadas sobre as regiões de interesse (ROIs) do esôfago (fúrcula, F, e apêndice xifóide, X) produzindo um sinal de tensão medido por um amplificador lock-in Stanford SR530. Para C marcamos as ROIs com reparos posicionados sobre F e X. Usamos uma câmara de circulação Orbiter Siemens para as aquisições dinâmicas de deglutição. A análise dos dados foi feita em um microcomputador PC 386. Os resultados foram (4.1+0.7)s para B e (3.7+0.9) s para C (R=0.6, P<0.07)


Abstract - This work shows the initial results for a new apparatus to study the esophageal transit time in assymptomatic persons for a yogurt bolus ( 1 O mi) uniformely labeled with 5g of ferrite powder (biomagnetic study. B) or 350MBq of 99mTc (scintigraphic study, C). For the B study the detection is made by means two pair of coils in opposite phase excited by a 1 O kHz sinusoidal voltage. We obtainted the signal response when the bolus traverses the coils placed on the regions-of-interest (RO!s) of the esophagus (furcula, F, and xiphoid process, X) and produces a signal voltage that is measured by a lock-in amplifier Stanford SR530. For C studies an Orbiter Siemens scintilation camera is used linked to a computer. The data analysis shows a (4.1±0.7)s in B studies and (3.7±0.9) s in C studies ( R=0.6, P<0.07 )


Subject(s)
Humans , Radionuclide Imaging , Magnetics , Esophagus/physiology , Gastrointestinal Transit , Esophageal Motility Disorders/physiopathology
3.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.93-94, graf.
Monography in Portuguese | LILACS | ID: lil-236262

ABSTRACT

O registro da atividade elétrica doo estômago, através da detecção do campo magnético associado foi detectado. A comparação desta atividade através do registro simultâneo do sinal elétrico e magnético foi feita através da função de correlação, análise de Fourier e testes estatísticos. A medida desta atividade pode auxiliar no diagnóstico de patologias do trato gastrointestinal. O método magnético apresenta a vantagem de ser completamente não invasivo.


Abstract - This work shows the study of the stomach electrical activity by the measurement of the magnetic field produced by the electrical currents generated at the stomach. A comparison between the electric and magnetic measurements was performed by the correlation function, Fourier analysis and statistical tests. These measurements can help on diagnostic of gastric-intestinal pathologies. This method has the advantage of the being non invasive


Subject(s)
Digestive System/physiopathology , Electromagnetic Phenomena , Magnetics , Fourier Analysis
4.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.99-100, tab, graf.
Monography in Portuguese | LILACS | ID: lil-236265

ABSTRACT

Apesar do método Cintilográfico se mostrar o melhor estabelecido para o estudo do trânsito digestivo, recentemente o método Biomagnético vem sendo utilizado, possuindo algumas vantagens em relação ao Cintilográfico. O objetivo deste estudo é comparar ambos os métodos para a medida de tempo de trânsito faringeano. Foram estudados 3 voluntários, obtendo-se valores consideravelmente diferentes do método Cintilográfico, possivelmente devido a resolução do detetor biomagnético.


Abstract - The Scintigrafic method is well established to study the digestive tract motility. Nevertheless, the Biomagetic method has recently been employed and it does have some advantages over the Scintigraphic one. The aim of this study is to compare pharyngeal transit time measured by both methods. Our preliminary results indicate that there is a difference between the values obtained with each method, probabily due to the Biomagnetic detector resolution


Subject(s)
Humans , Male , Adult , Radionuclide Imaging , Magnetics , Gastrointestinal Transit/physiology , Pharynx/physiology
5.
Braz. j. med. biol. res ; 28(11/12): 1327-31, Nov.-Dec. 1995. ilus, graf
Article in English | LILACS | ID: lil-161534

ABSTRACT

The initial results of a rnagnetocardiographic study comparing normal subjects to patients with right bundle branch block due to Chagas' and other diseases is presented. A quantitative criterion to discriminate normal healthy individuals from patients was proposed based on the amplitude of R and S waves detected by the magnetocardiograrn.


Subject(s)
Humans , Adolescent , Adult , Middle Aged , Bundle-Branch Block/diagnosis , Electrocardiography , Chagas Disease/complications , Magnetics
6.
Braz. j. med. biol. res ; 28(11/12): 1333-7, Nov.-Dec. 1995. graf
Article in English | LILACS | ID: lil-161535

ABSTRACT

The magnetic field produced by the fetal heart magnetocardiogram (FMCG) was measured by a single channel SQUID biogradiometer in an unshielded environment. FMCG amplitude ranged from 1 to 4 pT. Instantaneous fetal heart rate and averaged FMCG waveforms were computed. Spectral analysis was used to quantify fetal heart rate variability, and revealed peaks from 0.5 to 1.0 Hz, consistent with respiratory sinus arrhythmia. The duration of the QRS complex was approximately 50 msec, and its amplitude and shape showed strong spatial variation. Signal-to-noise ratio was inadequate for the study of P and T waves. These data show that this relatively simple and inexpensive instrument can be used for noninvasive in utero investigation of fetal heart activity without requiring a special environment.


Subject(s)
Humans , Female , Pregnancy , Fetal Heart/physiology , Electrocardiography , Fetal Monitoring/methods , Magnetics
7.
An. acad. bras. ciênc ; 60(2): 149-53, jun. 1988. ilus
Article in English | LILACS | ID: lil-68737

ABSTRACT

Os espectros de absorçäo obtidos por ressonância eletrônica paramagnética (REP) após oxidaçäo, armazenamento e aqueciemnto de Hb Zurich revelaram numerosos sinais na regiäo de alto campo (g=-) que säo indicativos da formaçäo de hemicromos. Espectros de absorçäo ópticos na regiäo visível obtidos da Hb Zurich oxidada ou de seu precipitado formado espontaneamente mostram aspectos característico da formaçäo de hemicromos. Os sinais de REP aumentam em g =-2) proporcionalmente ao decréscimo em g =-6,37. Além do mais, a relaçäo entre os valores de absorbância em 540 nm (heme) e 280 nm (proteína) näo se alteram durante o aquecimento da Hb Zurich a 50-C e säo similares no precipitado espontâneo desta hemoglobina en na HbA. Estes achados indicam que näo há perda do heme durante os estágios iniciais da desnaturaçäo da Hb Zurich


Subject(s)
Humans , Male , Electron Spin Resonance Spectroscopy , Hemeproteins/biosynthesis , Hemoglobins, Abnormal/metabolism , Hemoglobins, Abnormal/analysis , Hot Temperature
8.
Odontol. mod ; 15(2): 6-12, mar. 1988. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-852389

ABSTRACT

A quantidade de radiação a que é exposto um paciente durante um estudo radiológico depende diretamente das características dos filmes utilizados. Embora em radiologia oral os pacientes sejam submetidos a exposições mais baixas, quando comparadas com outras técnicas radiológicas, deve-se concentrar esforços para minimizar ao máximo a quantidade de radiação absorvida pela população. Uma forma efetiva de reduzir a exposição a raios X é escolher filmes rápidos, ou seja, filmes que proporcionem imagem radiológica em tempo mais curto. Sabe-se entretanto que a principal desvantagem baseia-se no fato de que filmes mais sensíveis diminuem a qualidade da imagem em termos de resolução. As curvas características foram determinadas utilizando-se uma minicunha de alumínio com 10 degraus, onde cada degrau possui 1 mm de espessura e uma área de 4 mm de aresta. Devido ao tamanho dos filmes as curvas foram determinadas através de um método mais viável, o qual consiste em expor a cunha a duas exposições com tempo de exposição dobrado. As curvas características foram encontradas para as diferentes marcas de filmes, onde pode ser notada uma sensível diferença entre os filmes. Tomando como base a exposição relativa do filme Kodak Ekta Speed, pode-se verificar que há necessidade de 55, 77 e 84//a mais de exposição, respectivamente para filmes Agfa-Gevaert, Rinn e Kodak Ultra Speed (Finep e Fapesp)


Subject(s)
Radiography, Dental/instrumentation , X-Ray Film